Cobalt-networks OPENGEAR PS-8300 Manuale Utente Pagina 19

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 40
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 18
8310 User Manual
(V 1.0.1) Page 19 of 40
SMPTE 269M Fault Reporting
Option
In This Chapter
This chapter contains the following sections:
Overview
Frame Connections
Details
Overview
The SMPTE 269M Fault Reporting system, also known as a SMPTE “alarm,” provides an indication if
one or more frame cards encounter a fault or an abnormal condition. This option is available when an
MFC-8310 or MFC-8310-N is installed in the Frame Controller Slot. The MFC-8310 is included if the
frame has cooling fans in the front door. The individual card(s) can report fault conditions to the
MFC-8310(-N) frame controller card, which in turn outputs to a BNC connector on the openGear
TM
8310 series frame. When the frame connection is interfaced with a customer-designed system of LEDs
or audible alarms, faults can be traced to a specific frame when a card fault occurs within that frame.